300 kW solar Panel (600 W × 500 panels)

A 300kW solar panel array is a common size for commercial and industrial solar projects, including hotels, resorts, factories, warehouses, farms, and commercial buildings.
For buyers planning a project of this size, the key questions are usually:
This guide focuses on the solar panel array itself. For detailed electrical parameters, mechanical data, temperature coefficients, and certifications, please refer to the Specification section on this product page.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
A 300kW solar panel array is already a medium-to-large commercial solar installation. Using 500 pieces of 600W high-efficiency monocrystalline solar panels, the array can generate approximately 480,000–520,000 kWh of clean electricity per year in Caribbean locations.
This amount of energy can typically support:
At peak sunlight, a 300kW array can produce close to 300kW of power, depending on site conditions, temperature, orientation, and system design.
The number of solar panels depends on the wattage of each module.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Using higher-power solar modules reduces the total number of panels, mounting structures, cable runs, electrical connections, and installation labor.
With 600W solar panels, a complete 300kW solar array requires approximately 500 modules.
For a 300kW commercial solar array, high-power monocrystalline modules are commonly used because they provide higher output per square meter and help reduce the total number of modules required.
Sunchees currently offers 600W monocrystalline solar panels, with double-glass bifacial options available for projects requiring higher energy yield and stronger environmental durability.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
For Caribbean hotels, factories, warehouses, and commercial buildings, durability is especially important because solar panels may be exposed to high humidity, salt mist, strong wind, and intense sunlight.
A 600W solar panel has an approximate area of 2.58 m². For 500 panels, the net module area is approximately 1,292 m².
However, the actual installation area must also include spacing, access paths, tilt angle, maintenance clearance, and site layout.
|
|
|
|
|
|
|
|
|
|
|
|
For most commercial rooftop projects, around 1,400–1,500 m² of usable roof space is enough to install a 300kW solar panel array.
Ground-mounted projects usually require more space because the rows need additional spacing to reduce shading.
|
|
|
|
|
|
|
|
|
|
|
|
A rooftop array is usually preferred when enough roof space is available. Ground-mounted installation is more suitable when the roof is too small, structurally unsuitable, heavily shaded, or reserved for future use.
Using 500 pieces of 600W solar panels, the total module weight is approximately 16.5 tons.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
This is the weight of the solar panels only. A complete installation also includes mounting structures, cable trays, electrical components, and installation accessories.
For rooftop projects, a structural assessment is recommended before installation.
The final roof load depends on the mounting method and roof type.
|
|
|
|
|
|
|
|
|
|
|
|
For newer industrial buildings, warehouses, and commercial roofs, a 300kW solar array is often feasible. For older buildings, lightweight roofs, wooden structures, or roofs with corrosion damage, an engineering assessment is necessary.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
A 300kW solar array is often a practical middle size for commercial buildings that have significant daytime electricity consumption but may not have enough space for a 500kW or 1MW installation.
Energy production depends on peak sun hours, performance ratio, orientation, shading, temperature, and maintenance.
Formula:
Annual Energy = System Capacity × Peak Sun Hours × 365 × Performance Ratio
For a 300kW solar array:
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
In the Caribbean, many locations receive around 5.5–6.0 peak sun hours per day, so a 300kW solar array can typically generate around 480,000–520,000 kWh per year.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
The combination of strong solar resources and high electricity costs makes commercial solar projects especially attractive in Caribbean and coastal markets.
Buyers searching for “300kW solar panel cost” may be referring to either:
For solar panel procurement, pricing is usually calculated in USD per watt.
|
|
|
|
|
|
|
|
|
The final module price depends on:
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
For Caribbean projects, buyers should also consider ocean freight, port charges, customs clearance, and local transportation.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Assuming an annual generation of around 500,000 kWh and a carbon emission factor of 0.7 kg CO₂/kWh:
|
|
|
|
|
|
|
|
|
|
|
|
For hotels, resorts, factories, and commercial buildings, this can support ESG targets, reduce fossil fuel dependence, and improve long-term energy sustainability.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
To estimate the right solar array size for your project, provide:
|
|
|
|
|
|
|
|
|
|
|
|
Based on this information, Sunchees can help estimate the required panel quantity, installation area, expected annual energy production, and suitable procurement plan
Solar Panel Electrical Parameter at STC
|
Maximum Power |
600W |
|
Operating Voltage at Maximum Power |
44.66 V |
|
Operating Current at Maximum Power |
13.44 A |
|
Open Circuit Voltage |
52.81 V |
|
Short Circuit Curent |
14.46A |
|
Module Efficiency |
23.20 |
|
Power Tolerance |
0~+5W W |
*Standard test conditions(STC):airmass AM1.5,irradiance 1000W/m2,cell temperature 25℃.
Electrical Parameter at NOCT
|
Maximum Power |
445W |
|
Operating Voltage at Maximum Power |
40.62V |
|
Operating Current at Maximum Power |
10.97A |
|
Open Circuit Voltage |
49.44V |
|
Short Circuit Current |
11.63A |
Solar panel Data
|
Cell Type |
182Monocrystalline |
|
Number of Cells |
144 pcs(6x24) |
|
Module Dimension |
2279*1134*30mm |
|
Weight |
33kg |
|
Glass |
3.2mm high transmittance,anti-reflection coated tempered glass |
|
Back Sheet |
transparent |
|
Frame |
Anodized aluminum alloy |
|
Junction Box |
Protection degree IP68 |
|
Cable |
4mm区,+400-200MM/±1400MM Photovoltaic dedicated cable |
|
Quantity of diodes |
3 |
|
Wind Load/Snow Load |
2400pa/5400pa |
|
Connector |
Compatible MC4 connector |
Company profile
Sunchees was founded in 2008, head office and factory is located in Foshan, Guangdong. China,but its sales network has spread to more than 100 countries and regions around the world.

Main business: solar power system one stop solutions, solar inverter , solar air conditioner system, solar street light system . solar DC power system ect .

Sunchees products are widely used in home, agriculture, industry, finance, electric power, transportation, security, new energy. Its stable and excellent performance have been widely recognized.
| Parameter Name | Parameter Value |
|---|---|
| Solar Panel - Max power | 600W * 500PCS |
| Solar Panel - Solar Cell | Monocrystalline |
| Solar Panel - Maximum Power Current (IMP) | 13.90A |
| Solar Panel - Output Tolerance | ±3% |
| Solar Panel - MaximumPowerVoltage(VMP) | 39.18V |
| Solar Panel - Open Circuit Voltage(VOC) | 47.40V |
| Solar Panel - Short Circuit Current(ISC) | 14.01A |
| Solar Panel - Temperate coefficient of Isc | 0.05%/℃ |
| Solar Panel - Frame | Aluminum alloy frame |
| Solar Panel - Temperature range | -40℃~ +85℃ |
| Solar Panel - Product Dimension | 2115 * 1052 *40 mm |
| Solar Panel - Weight | 20.5 kg |
| Solar Panel - Certificates | TUV、IEC,CE |